Your enquiry cart is empty!
Categories
- Analogue Products
- Redundancy Support
-
Fiber Media Converters
- RS-232 to Multimode Fiber Optic Converter (rdc232MFO)
- RS-232 to Singlemode Fiber Optic Converter (rdc232SFO)
- RS-485 to Multimode Fiber Optic Converter (rdc485MFO)
- RS-485 to Singlemode Fiber Optic Converter (rdc485SFO)
- Multimode to Multimode Fiber Optic Repeater / Extender (rdcMMFO)
- Multimode to Singlemode Fiber Optic Converter (rdcMSFO)
- New rdc485fh series
- Ethernet to Fiber Optic Converter (rdcEnetFO)
- RS-232 / RS-485 / RS-422 to Fiber Optic Converter (rdcFOu)
- Single/Dual Port Fiber Optic Converter with Digital I/O (rdcFoms-DIO)
- RS-232 to Fiber Optic Converter (Multi-mode) (rdc232fo)
- RS-232 to Fiber Optic Converter (Single-mode) (rdc232fos)
- RS-485 to Fiber Optic Converter (Multi-mode) (rdc485fo)
- RS-485 to Fiber Optic Converter (Single-mode) (rdc485fos)
- Multimode Fiber Optic Repeater (rdcFOmm)
- Single Mode to Multimode Fiber Optic Converter (rdcFOms)
- Device Servers
- Isolated Converters
-
Isolated Repeaters
- Isolated 2-wire RS-485 Repeater (rdc485ir3)
- Isolated RS-485 Repeater (2 or 4-wire) (rdc485ir)
- Isolated RS-422 Repeater (rdc422ir)
- Isolated 3-wire RS-232 Repeater (rdc232ir3)
- Isolated 5-wire RS-232 Repeater (rdc232ir5)
- Isolated 9-wire RS-232 Repeater (rdc232ir9)
- Self-Powered 3 wire RS-232 Isolator (rdc232iso)
- Lightning Protection Units
Order Options
Robust DataComm products are manufactured with build-options to suit different needs. There are options for isolation, input power and connector types.
Isolation Options (Non-Fiber Products)
rdcxxxxx 4p - Full 4 of 4 ground 1 to 2.5 KV galvanic/optical isolation
4 of 4 ground isolation means all data grounds are 100% isolated from each other and the power supply ground. Like 3 of 3 ground design, this is always the safest design option. All redundancy - supporting products (hubs, arbitrators etc) are based on this design.
4 of 4 ground isolation means all data grounds are 100% isolated from each other and the power supply ground. Like 3 of 3 ground design, this is always the safest design option. All redundancy - supporting products (hubs, arbitrators etc) are based on this design.
rdcxxxxx 3p - Full 3 of 3 ground 2500v galvanic/optical isolation
3 of 3 ground isolation means both data grounds are 100% isolated from each other and the power supply ground. In DC powered systems, this is always the safest design option. All RDC products are engineered with this design in mind.
3 of 3 ground isolation means both data grounds are 100% isolated from each other and the power supply ground. In DC powered systems, this is always the safest design option. All RDC products are engineered with this design in mind.
rdcxxxxx 2p - Partial 2 of 3 ground 2500v galvanic/optical isolation
2 of 3 ground isolation means one data ground is 100% isolated from both the other data ground and the power supply ground, while the other data ground is sharing the same as the power supply ground. RDC products of this design can be used when both the local device and RDC device share the same power supply (and therefore the same ground). Most "opto-isolated" data communication products on the market are built on this design, which will cause issues if the local device and RDC device are on different grounds.
2 of 3 ground isolation means one data ground is 100% isolated from both the other data ground and the power supply ground, while the other data ground is sharing the same as the power supply ground. RDC products of this design can be used when both the local device and RDC device share the same power supply (and therefore the same ground). Most "opto-isolated" data communication products on the market are built on this design, which will cause issues if the local device and RDC device are on different grounds.
Isolation Options (Fiber Products)
Fiber Optics offer intrinsic isolation and also do not have or need of a ground point.
Hence, when classifying the number of isolated ports in RDC’s fiber converters, the fiber ports are not taken into consideration.
rdcxxxxx 1p - Non-isolated converter
Non-isolated means this converter assumes the electrical data comm ground is the same as the power supply ground. This assumption is Ok if both the device and converter share the same power supply (and therefore the same ground), but it will cause problems if they have subtly different grounds.
Non-isolated means this converter assumes the electrical data comm ground is the same as the power supply ground. This assumption is Ok if both the device and converter share the same power supply (and therefore the same ground), but it will cause problems if they have subtly different grounds.
rdcxxxxx 2p - Full 2 of 2 ground 2500v galvanic/optical isolation
Full 2 of 2 ground isolation means the electrical data comm ground is 100% isolated from the power supply ground. In DC powered systems, this is always the safest design option.
Full 2 of 2 ground isolation means the electrical data comm ground is 100% isolated from the power supply ground. In DC powered systems, this is always the safest design option.
Power Options
rdcxxxxx dv 12v & 24v (9 to 36v) DC
Accepts unregulated 9 to 36v DC power supply. Suitable for industrial 24vdc supplies, 12v or 24v battery systems, or supply from any low-cost DC transformer pack. Fully in-rush and surge protected.
rdcxxxxx av 9 to 24v AC or DC
Accepts unregulated 9 to 24v AC power or 9 to 36v DC power supply. Suitable for industrial 24vdc or 24vac supplies, 12v or 24v battery systems, or supply from any low-cost AC or DC transformer pack. Fully in-rush and surge protected. -av power option must be ordered with full optical/galvanic isolation.
rdcxxxxx hv 48v ± 20% (38 to 58v) DC
Accepts unregulated 48v DC power ± 20%. Suitable for industrial +48vdc or -48vdc power supplies. Fully in-rush and surge protected. -hv power option must be ordered with full optical/galvanic isolation. It cannot be supplied with partial isolation.
rdcxxxxx gv 12v 24v & 48v (9 to 48v) DC
Accepts unregulated 9 to 48v DC power supply. Suitable for industrial 24vdc & 48vdc supplies, 12v or 24v battery systems, or supply from any low-cost DC transformer pack. Fully in-rush and surge protected.
rdcxxxxx 5v - 5v DC ± 5%
Accepts well-regulated 5v DC +/- 5% power supply. Suitable for OEM or panel use with clean, well-regulated power supplies. (NOT SUITABLE FOR BATTERY POWER!)
Connector Options
rdcxxxxx dd 9-pin D-sub shell connecter
Robust DataComm uses only quality parts from vendors with published specs. We know that all of our 9-pin connectors come with at least 30 micron gold plating rated at 500 insertion cycles. 'Gold-plating' results in a consistant layer and thickness of gold on the contacts.
Most other commercial (and 'industrial' products by commercial suppliers) use lowest-cost parts with 'gold-flash' rated at 30-50 insertion cycles. With 'gold-flash' the quantity of gold on the contacts is unknown; it is a variable of the process. It doesn't take many disconnects during troubleshooting to permanently damage 'gold-flash' parts. Insist on quality 'gold-plating' of 30 micron or better.
rdcxxxxx cc - Removeable screw terminals with 2.5mm capacity
Robust DataComm uses only quality parts from vendors with published specs. We know that all of our screw terminals have consistent force and spring ratings. They will hold your wires indefinitely without vibrating loose.
rdcxxxxx st - ST Bayonet-style fiber optic connector
rdcxxxxx sc - SC Subscriber/Standard fiber optic connector
rdcxxxxx fc - FC Ferrule fiber optic connector
rdcxxxxx sma - SMA screw-style fiber optic connector
Connector Options
rdcxxxxx cf - Conformal coating, 5000v rating (Not available for all products. See datasheets for more details.